Centrifuges: General Care Tips

  • Some paperwork must be done, before arriving at the details of centrifuge care. First, there are guides—your centrifuge came with one, also it carries a portion on maintenance and cleaning, and quite possibly a listing of chemicals/cleaners/disinfectants that are safe to utilize, along with a list of those that are not. A duplicate is likely accessible on the internet, and ought to be downloaded and printed in case the manual is lost. It’s a good idea to read it, and keep it handy, not only during initial runs but during the first cleanings also. A maintenance log should be kept so that appropriate maintenance could be confirmed to come full circle. This is especially significant in warranty claims.
  • The centrifugal field which accelerates the separation process also uses big forces on the rotor material. The centrifuge is severely damaged as well if a rotor fails. For this reason, some easy precautions ought to be observed. Rotors were created to be run up to their maximum speed using a load of a specific weight. One should never attempt to run a rotor at a rate higher than the one designated by its manufacturer. Also, if high density solutions (greater than 1.2 g/mL, for instance) are used, the run speed must be reduced to prevent undue stress on the rotor. Consult your instruction manual for precise directions.
  • Any glass fragments should be taken off the buckets, adapters, rubber liners, and rotor chamber before the following run is made. It must be cleaned up also, in case you find gray dust, which results from sandblasting by glass particles of the rotor chamber. You clean the chamber between each run to make sure this dust is discharged from the centrifuge, and need to make several dry runs without samples.
  • Consult your manual to be certain they are compatible with the various plastics and metals including the centrifuge, the rotor, the tubes, and other accessories if you intend to centrifuge any uncommon solvents or solutions. These same precautions must be detected with any solvents used for sterilization purposes.
  • Portions of the mist will likely be fine enough to form a relatively secure aerosol that will tend to be dispersed throughout the lab. Such spills should be thoroughly cleaned up before running the centrifuge.
  • Blood should be handled with respect for this possibility during all lab exploitation, including centrifugation.
  • From time to time, you’ll have questions about the actual operation as well as upkeep of your centrifuge. The instruction manual provided with each device was created to answer these questions. It kept handy for future reference, and ought to be read before making your first run.
  • (It is also often recommended to get staff assigned to this and other jobs.) While sometimes inconvenient, adhering to a regular program is cost-efficient and saves time in the long run.
  • For hazardous spills, your laboratory or association is going to have protocol that could contain everything from kinds of protective gear and merchandises, such as spill kits, to be used, to reporting and security procedures. It truly is essential that they are followed and that these are understood. It is often true that shortcuts, because they skip a step or detail, wind up taking more time later. Understand the types of samples being run in the laboratory; keep this info current, notably in a shared lab. This will definitely help ascertain whether protocols or any unique merchandises are needed for cleaning. The manual will probably be the very best guide to the goods and procedures to use for cleaning every one of these.
  • Centrifuge maintenance, as the name says, is to be understood as an everyday tool to maintain security and best condition of laboratory devices. To follow cleaning and care recommendations is tremendously significant in the event of pollution with salts and compounds. In case of long term exposure aggressive substances can develop corrosive areas on rotors and rotor-buckets, which might always grow and form little holes if ignored. This farther facilitates corrosion procedures as protective coatings are missing on those areas, if little scratches and cracks are present on the rotor surface. In ways that makes centrifugation procedures unsafe, pails or rotors could be damaged in case of advanced corrosion. In worst case, damaged rotors can even cause a crash. Yet the centrifuge and rotor themselves might be destroyed.
    Top quality aluminum rotors and rotor -buckets are usually protected against corrosion caused by commonly-used lab compounds, for example by way of an anodized coating. However competitive compounds can nevertheless damage the gear! Such chemicals include concentrated acids concentrated and light alkalis, solutions including copper ions mercury ions and other heavy metal ions, chlorinated hydrocarbons, and concentrated saline solutions. Generally steel rotors are protected against corrosion by the use of coatings too, but of course additionally they need constant care.
  • Centrifuges Remove pails and rotor from the centrifuge. For refrigerated centrifuges: Leave centrifuge lid defrost and open the ice on the rotor chamber surface. If your centrifuge includes a water collection tray, empty
  • We recommend checking the rotors and rotor bores visually for corrosion and deposit on a monthly or weekly basis. Plates or damaged tubes should not be centrifuged. Significant information regarding care and cleaning can not only be uncovered in the operating manual of your centrifuge, but in addition in this paper. If unsure concerning the cleaning or decontamination methods of the centrifuge or rotor, one
    should contact the manufacturer and follow his recommendation. An authorized technician should be reached, if in doubt whether a rotor remains safe.
    And clean it, then wipe the rotor chamber with a damp cloth. The outside of the centrifuge and also the rotor chamber should be cleaned frequently with a moist cloth and neutral detergents. Change off the centrifuge, before you do so.
  • When there’s broken glass: Retrieve the bigger broken glass with forceps, remove little and powder shards with a damp lint-free fabric. Consume blood with gauze or paper towel and afterwards, seal the material in a biohazard bag for safe disposal. Wipe the parts that are contaminated with
    neutral agents for cleaning and disinfection (e.g. diluted neutral alcohol-based disinfectant or 70% isopropanol mixture). Use a soaked gauze or lint-free fabric.
    If necessary, remove still contaminated pail caps out of centrifuge to decontaminate places that are difficult to reach, rotor lid, pails, and rotor. With distilled water the equipment ought to be wiped after decontamination.
  • Use inert cleaning solutions (alcohol or alcohol-based disinfectant) along with a soft cloth to clean your rotors and accessories. Wipe contaminated parts with neutral agents for cleaning and disinfection (e.g. diluted inert alcoholbased disinfectant or 70% isopropanol mixture). Use a soaked gauze or lint-free material. In case of some competitive liquid on your own centrifuge gear, please clean it instantaneously. When there is stubborn spot, clean with a plastic scrub pad and rinse equipment with distilled water.
    Liquid dry thoroughly with a soft cleaning cloth, and could flow into rotor cavities. We strongly urge cleaning buckets and rotors immediately, as the surface wills corrode. When there’s a need to wash the rotor’s boreholes or tube cavities, utilize a stiff test-tube brush that’s end bristles along with a nonmetallic tip. For swing-bucket rotors, ensure the grooves where the buckets are fitted are free of pollution. Take care to make sure that the pails can still swing freely.
  • Alternatively dry rotors, rotor accessories and boreholes with absorbent towels. To keep aerosol-tight hats/caps and seals from becoming worn out/damaged, shop lids/caps separately from the bucket/rotor.
  • To protect human beings from contamination from pathogens or samples, sterilization of rotors and accessories may be desired. Sterilization is a term referred to a process which removes all types of microbial life, including transmissible agents such as bacteria, viruses, fungi, spore forms etc.
    For autoclaving at 121 °C, a number of rotors in the marketplace have been analyzed. Particularly the aluminum made fixed-angle and swing out rotors have been vigorously tested and approved within this setting. They possess a special anodized coating which protects the metal from corrosion effects that are deeper. Steel made rotors are usually of limited suitability for autoclaving. Please ask the manufacturer about autoclaving chances in case you are in doubt about your rotor.
  • To realize an excellent chemical resistance against sodium hypochlorite and phenol, acetonitrile, DMSO, acetone, trichloroacetic acid, acetic acid, Eppendorf offers another type of aluminum fixed-angle rotor with a PTFE coating that is special. This coating is applied on top of the actual anodic coating. Autoclaving (121 °C, 20 min.) this rotor sort
    even improves the already enhanced chemical resistance as a result of material properties of the coating.